Optima HammerHead Electronics Instruction Manual
The Hammerhead, also has handsets called the primary and secondary, but each
has different purpose and functions. The primary is responsible for maintaining the
selected set-point, displaying the measured PO
2
for the three main oxygen sensors, time,
depth and decompression information. The secondary is a backup display for the main
oxygen sensors, and controller for the DIVA Heads-Up display. The secondary DOES
NOT CONTROL the solenoid, it is meant to allow the diver to manually maintain the
breathing loop in the event of a primary failure. The only common point between the
primary and secondary is the oxygen sensors. Each controller has an independent power
source.
SETUP and INSTALLATION
The Hammerhead allows for the tracking of sensor health by allowing the user to
display millivolt readings for each sensor. This is accomplished by utilizing the “MV
DISPLAY” option located under the “OPT” menu on both the primary and secondary
handsets once the harness is connected. Recording the millivolt readings for each cell
when exposed to air and oxygen will expose cells that are going non-linear. The actual
oxygen percentage used in calibration should also be recorded.