The Imperial – Metric setting selects system of
units that will be used for displaying depth on the
current hardware revision; future hardware upgrades
will add temperature measurement. The current
selected units will be displayed, pressing the LEFT
button will toggle and RIGHT will select.
The solenoid firing function sets the set-point
control algorithm. The HammerHead supports two
automatic control methods: “Standard Mode” and
“Juergenson Mode”, plus “Manual Mode”. Standard
mode uses the setting from “Standard Error”, while
“Juergensen” is an adaptive mode that changes firing
duration and rate based on depth and ascent/descent
rates “Manual Mode” requires the diver to maintain the loop PO
2
automatic PO
2
control
is disabled. The handset will override the manual setting and fire the solenoid if the loop
PO
2
drops to a 0.19.
This option selects the required period of time
that must elapse before the handset enters shutdown/low
power mode. The valid settings are two through thirty
minutes. Care must be taken when choosing this timeout
period. A long timeout drains batteries faster, while a
shorter timeout saves power. Choose a timeout period
that is longer than the expected time required to enter
the water. ANY TIME the loop is used out of the water, care must be exercised. Once the
handset enters shutdown mode PO
2
monitoring and control is inactive. Failure to monitor
the handsets may lead to a hypoxic loop and eventual unconsciousness.
This option displays the raw milivolt output on
each of the three sensors. While in this mode the
backlight remains illuminated and does not timeout.
Pressing either button exits the test. This option should
be used to record the output of each sensor while in AIR
and Oxygen
This option sets the allowable error before the
solenoid fires in “Standard Mode”. The valid range is
from 1% to 10%. A lower value is not necessarily a
Imperial—Metric
NEXT SELECT
Solenoid Firing
NEXT SELECT
Auto Shutdn Rate
NEXT SELECT
MV Display
NEXT SELECT
Standard Error
NEXT SELECT