The next option is setting the level of
conservatism for the decompression model. The original
software has eleven levels of conservatism, setting “1”
being the least conservative and setting “11” being the
most conservative. The GF-low and GF-high limits are
decreased equally with increasing level of conservatism
forcing deeper stop depths and lower allowed limits of
inert gas loading. Starting with version 4.5, true gradient factors are employed with
separate limits determining where the stops begin and when to proceed to the next level.
There are now five preprogrammed gradient factor sets and one user programmable
setting. The selected gradient factor can be changed during the dive allowing full control
over the dive profile. The user programmable selection can even be reprogrammed while
in dive mode.
Changing the conservatism requires scrolling the past the set-point selections until
the “OPT” screen is displayed then selecting, scroll past the “Define Gas” until
“Concervatism” is displayed. Press the right button to select, The original software will
now allowing through 11 levels without any additional information. Starting with version
4.5 there are now 6 selections each will display the
associted GF-Low and GF-High settings associated
with the selection. The conservatism level is selected
with the right button then must be confirmed. All
confirmations on the HammerHead are done purposedly
with the left button selecting “Yes” to prevent
accidental confirmations due to double key presses.
For a complete explanation of Gradient Factors see Erik Bakers paper on
Deep Stops available at ftp.decompression.org and many other decompression software
Conservatism
NEXT SELECT
GF [4] [30/ 75]
NEXT SELECT
GF[5] [35 70]
NEXT SELECT
GF User [95/100]
NEXT SELECT
GF [1] [10/100]
NEXT SELECT
GF [2] [20/ 95]
NEXT SELECT
GF [3] [25/ 85]
NEXT SELECT
Confirm