decompression obligation. NO conservatism setting or decompression plan can
guarantee ZERO risk of decompression sickness!
The next option allows the entry of the custom gradient discussed in the previous
section. The first value entered is the GF-High, followed by the GF-Low setting.
This is necessary to allow setting the upper limit for the GF-Low setting 5% below the
GF-High value.
This option allows the defining of five set-points.
After choosing the “Define Set Point” option, the handset
will begin prompting with “Set Point 1” the left button
scrolls to the next set-point while the right button enters
the programming for the displayed set-point. The handset
will display the current value. The left button is used to
change the value of the chosen set-point. This starts with
the current setting, incrementing to a maximum of 1.6 and rolling over back to the low
value of 0.4. Once the desired value is displayed, the right button is used to select the
setting. Values that are programmed on the primary should also be programmed on the
secondary. The diver needs to select the same set-point on both handsets, since alarm
generation on the secondary is based on variation from the selected setpoint.
Once the calibrate option is selected the next
screen will show “Fill Loop w/o2”, with prompts for
“Ready “ and “Cancel”. This action is confirmed with
the LEFT button. This prevents a double press selecting
this screen from inadvertently applying this change. The
calibration technique used with the Hammerhead
electronics is the same as most other CCRs and requires
a different approach from the original Inspiration electronics. The HammerHead holds a
very stable calibration; it is not necessary to constantly recalibrate the handsets. The
recommended method is to evacuate all the gas from the loop, flush with oxygen and
repeat at least FOUR times. On the final flush, totally fill the loop until the OPV releases.
Go to the “MV display” screen and take note of the values, exit this screen to prevent the
Custom Gradient
Gf Hi = [100]
Custom Gradient
NEXT SELECT
Custom Gradient
Gf Lo = [ 95]
Define Set Point
NEXT SELECT
Calibrate O2
NEXT SELECT